  1.                          SECTION 08162
  2.  
  3.                      ICU/CCU SLIDING DOORS
  4.  
  5. NOTE ** Dor-O-Matic, ICU/CCU-hospital sliding doors.
  6. NOTE **
  7. NOTE ** This section is based on the products of Dor-O-
  8.         Matic, which is located at:
  9. NOTE **    7530 W. Wilson Avenue
  10. NOTE **    Harwood Heights, IL  60656-4786
  11. NOTE **    Tel:  (708) 867-7400
  12. NOTE **    Tel:  (800) 543-4635
  13. NOTE **    Fax:  (708) 867-0291
  14. NOTE **
  15. NOTE ** Dor-O-Matic is one of the oldest, most experienced,
  16.         and most innovative manufacturers of automatic door
  17.         equipment in the world.  This section covers only a
  18.         part of their product line:  "ICU/CCU-Hospital"
  19.         sliding doors with accompanying accessories,
  20.         including necessary hardware.  See their other
  21.         sections for automatic swinging doors, automatic
  22.         sliding doors, automatic folding doors, low-energy
  23.         door operators, and fire door operators.
  24. NOTE **
  25. NOTE ** SECTION 08162 - ICU/CCU SLIDING DOORS, Copyright
  26.         1998, The Architect's Catalog, Inc.
  27.  
  28. PART 1  GENERAL
  29.  
  30. 1.1 SECTION INCLUDES
  31. NOTE ** Select paragraphs below applicable to project.
  32.         Standard header: 6-3/4 inches (170 mm) high, 4
  33.         inches (100 mm) wide; Slim-Line header: 2-1/2
  34.         inches (63 mm) high, 4-1/2 inches (114 mm) wide;
  35.         Slim-Line Telescopic header: 2-1/2 inches (63 mm)
  36.         high, 7 inches (178 mm) wide.
  37.  
  38.     A.  Two-leaf sliding doors, panels, jambs, and hardware.
  39.         1.  Standard.
  40.         2.  Slim-Line.
  41.         3.  With floor track.
  42.         4.  Trackless.
  43.  
  44.     B.  Three-leaf sliding doors, panels, jambs, and hardware.
  45.         1.  Standard.
  46.         2.  Slim-line.
  47.         3.  Slim-Line telescopic.
  48.         4.  With floor track.
  49.         5.  Trackless.
  50.  
  51.     C.  Four-leaf sliding doors, panels, jambs, and hardware.
  52.         1.  Standard.
  53.         2.  Slim-Line.
  54.         3.  With floor track.
  55.         4.  Trackless.
  56.  
  57.     D.  Slim-Line telescopic six-leaf sliding doors, panels,
  58.         jambs, and hardware.
  59.         1.  With floor track.
  60.         2.  Trackless.
  61.  
  62. 1.2 RELATED SECTIONS
  63. NOTE ** Delete sections below not relevant to this project;
  64.         add others as required.
  65.  
  66.     A.  Section 03300 - Cast-in-Place Concrete:  Preparation of
  67.         concrete to accept recessed floor track.
  68.  
  69.     B.  Section 07900 - Joint Sealers.
  70.  
  71.     C.  Section 08800 - Glass and Glazing.
  72.  
  73.     D.  Section _____ - ____________________________.
  74.  
  75. 1.3 REFERENCES
  76. NOTE ** Add other references below as required.
  77.  
  78.     A.  NFPA 101 - Safety to Life from Fire in Buildings and
  79.         Structures.
  80.  
  81. 1.4 DEFINITIONS
  82.  
  83.     A.  SX Panel:  Sliding panel which swings open upon pushing.
  84.  
  85.     B.  SO Panel:  Sidelite panel, normally stationary, which
  86.         will swing open in an emergency.
  87. NOTE ** Include the following two paragraphs if trackless
  88.         Slim-Line telescoping doors are required for the
  89.         project.
  90.  
  91.     C.  X Panel:  Sliding panel in trackless Slim-Line
  92.         telescoping doors, unable to swing.
  93.  
  94.     D.  O Panel:  Sidelite panel in trackless Slim-Line
  95.         telescoping doors, unable to swing.
  96.  
  97. 1.5 SUBMITTALS
  98.  
  99.     A.  Submit under provisions of Section 01300.
  100.  
  101.     B.  Product Data:  Manufacturer's catalog data, detail
  102.         sheets, and specifications.
  103.  
  104.     C.  Shop Drawings:  Prepared specifically for this project;
  105.         show dimensions of doors, sidelites, details of
  106.         construction, and interface with other products.
  107.  
  108.     D.  Operating and Maintenance Data:  Operating and
  109.         maintenance instructions, and parts lists.
  110.  
  111. 1.6 QUALITY ASSURANCE
  112.  
  113.     A.  Installer Qualifications:  Factory-trained, with minimum
  114.         3 years experience.
  115.  
  116.  
  117. PART 2  PRODUCTS
  118.  
  119. 2.1 MANUFACTURERS
  120.  
  121.     A.  Acceptable Manufacturer:  Provide products made by Dor-O-
  122.         Matic, 7350 West Wilson Avenue, Harwood Heights, IL 60656-
  123.         4786.  ASD.  Tel: (708) 867-7400 or (800) 543-4635.  Fax:
  124.         (708) 867-0291.
  125.  
  126.     B.  Requests for substitutions will be considered in
  127.         accordance with provisions of Section 01600.
  128. NOTE ** Delete paragraph above or below; coordinate with
  129.         Division 1 requirements.
  130.  
  131.     C.  Substitutions:   Not permitted.
  132.  
  133.     D.  Provide all ICU/CCU sliding doors from a single
  134.         manufacturer.
  135.  
  136. 2.2 DOORS AND FRAMES
  137. NOTE ** ICU/CCU-hospital sliding doors are available from
  138.         Dor-O-Matic in complete packages, including
  139.         aluminum doors, sidelites, frames, and hardware.
  140.  
  141.     A.  Doors, Sidelites, Headers, and Trim:  Extruded aluminum
  142.         alloy 6063-T5, nominal 0.125 inch (3.17 mm) wall
  143.         thickness.
  144.         1.  Door and Sidelite Construction:  Heavy-duty
  145.             interlocked sections, through-rod bolted
  146.             construction; steel corner support at hinge stile of
  147.             carrier-suspended SX panels to eliminate sag in
  148.             sliding or breakout mode.
  149. NOTE ** Include the following three subparagraphs for Slim-
  150.         Line trackless doors (not for trackless
  151.         telescoping).
  152.             a.  Combination Support Guide: SX panel.
  153.             b.  Roller Assembly:  SO sidelite panel.
  154.             c.  Glass Jacking Screw Assembly:  SO sidelite panel.
  155. NOTE ** Delete the following paragraph if electrical
  156.         grounding is not required for the project.
  157.         2.  Electrically ground sliding doors against static
  158.             electricity.
  159.         3.  Door Hanger Brackets:  Nylon wheels with hardened
  160.             steel bearings.
  161. NOTE ** Include the following paragraph for Standard doors.
  162.         4.  Door Suspension System:  SX breakout panels suspended
  163.             over centerline of door.
  164.         5.  Glazing Stops:  5/8 inch (15.87 mm) high.
  165. NOTE ** Include the following two paragraphs for Slim-Line
  166.         trackless doors (not for trackless telescoping).
  167.         6.  Pivot Base Plate:  Under each SO sidelite panel.
  168.         7.  Concealed Floating Pivots:  In each panel.
  169. NOTE ** Select the first paragraph below for Standard doors
  170.         with floor track, the second for Slim-Line doors
  171.         with floor track, the third for trackless Slim-Line
  172.         doors, and the fourth for Slim-Line telescopic
  173.         doors (with or without floor track).
  174.         8.  Headers:  6-3/4 inches (170 mm) high, 4 inches (100
  175.             mm) wide, with full-width swing-out access cover.
  176.             a.  Built-in anti-riser system.
  177.         9.  Headers:  2-1/2 inches (63 mm) high, 4-1/2 inches
  178.             (114 mm) wide.
  179.             a.  Built-in anti-riser system.
  180.         10. Headers:  2-1/2 inches (63 mm) high, 4-1/2 inches
  181.             (114 mm) wide with extruded aluminum stop bar mounted
  182.             to underside in door opening to prevent SX panel from
  183.             swinging until slid back to full position.
  184.             a.  Built-in anti-riser system.
  185.         11. Headers:  2-1/2 inches high (63 mm), 7 inches (178
  186.             mm) wide.
  187.         12. Hardware:  Door handles, recessed door pulls, and
  188.             other hardware required for normal and emergency
  189.             egress operation per NFPA 101.
  190. NOTE ** Select the first paragraph below for Standard doors
  191.         with floor track, the second for Slim-Line doors
  192.         with floor track, the third for trackless Slim-Line
  193.         doors, the fourth for Slim-Line telescopic doors
  194.         with floor track, and the fifth for trackless Slim-
  195.         Line telescopic doors.
  196.             a.  Emergency Egress:  Non-adjustable magnetic latch
  197.                 on SX panels and emergency breakaway release on
  198.                 SO panels, allowing 90 degree swing of both
  199.                 panels under minimum pressure from any position
  200.                 in SX panel cycle.
  201.             b.  Emergency Egress:  Spring-loaded stainless steel
  202.                 ball detent latch on SO and SX panels, allowing
  203.                 90 degree swing of both panels under minimum
  204.                 pressure from any position in SX panel cycle.
  205.             c.  Emergency Egress:  Flush bolt in SO panel
  206.                 releasable after SX panel is in full open
  207.                 position past aluminum stop bar, allowing 90
  208.                 degree swing of both panels as a single unit
  209.                 under field-adjustable pressure.
  210.             d.  Emergency Egress:  Spring-loaded stainless steel
  211.                 ball detent latch on SO and SX panels, allowing
  212.                 90 degree swing of both panels under minimum
  213.                 pressure from any position in SX panel cycle.
  214.             e.  Emergency Egress:  Spring-loaded stainless steel
  215.                 ball detent latch on SX panel(s), allowing 90
  216.                 degree swing of SX panel(s) under minimum
  217.                 pressure from any position in panel cycle.
  218. NOTE ** Delete all but one of the following five finish
  219.         paragraphs.  Dark bronze and natural anodizing are
  220.         standard options -- all other finishes are extra.
  221.         13. Finish:  Dark bronze anodized.
  222.         14. Finish:  Natural aluminum anodized.
  223.         15. Finish:  Black anodized.
  224.         16. Finish:  Kynar 500(tm) coating; color: _____________.
  225.         17. Finish:  Clad, ______________.
  226. NOTE ** Delete the following paragraph if only trackless
  227.         doors are required.
  228.  
  229.     B.  Track:  Recessed in floor.
  230.  
  231.  
  232. PART 3  EXECUTION
  233.  
  234. 3.1 EXAMINATION
  235.  
  236.     A.  Verify that door openings are plumb, square, and ready
  237.         for installation of ICU/CCU sliding doors.
  238. NOTE ** Delete the following paragraph for trackless
  239.         installations.
  240.  
  241.     B.  Verify that concrete is properly prepared to receive
  242.         recessed floor track.
  243.  
  244. 3.2 INSTALLATION
  245.  
  246.     A.  Install ICU/CCU sliding doors, frames, hardware, and
  247.         accessories in accordance with manufacturer's
  248.         instructions.
  249. NOTE ** Delete the following paragraph for Slim-Line
  250.         trackless installations.
  251.  
  252.     B.  Install floor track in accordance with manufacturer's
  253.         instructions.
  254.  
  255. 3.3 ADJUST AND CLEAN
  256.  
  257.     A.  Adjust doors for proper operation, without binding or
  258.         scraping and without excessive noise.
  259.  